C1 C2 Certified Seismic Throughbolt

FDG carries a full range of C1 C2 Certified Seismic Throughbolt Anchors so you can be sure you comply with the New Zealand Building Code. Full testing results and compliance certification is available to ensure ease of compliance and technical submission. View our full range of Seismic Anchors here.

Note: These Throughbolts comply with AON’s Technical Note 21-57 regarding NZS 4541:2020 – Automatic Fire Sprinkler Systems, which requires all “post-installed” masonry fixings to be C2 rated. Read more here.

 Features and Benefits:

  • C1 C2 Certified Seismic Throughbolt with ETA Approval
  • New generation of throughbolt with unique corrosion-resistant coating
  • High performance in cracked and non-cracked concrete confirmed by ETA Option 1
  • Highest quality ensures maximum load capability
  • For applications requiring fire resistance up to 120 minutes
  • Suitable for reduced embedment to avoid contact with reinforcement
  • Embedment depth markings help to ensure precise installation of the anchor
  • Design of R-HPTII allows drilling and installing directly through the fixture and helps to reduce installation time
  • Fire resistant
C1 C2 Certified Seismic Anchors
C1 C2 Certified Seismic Throughbolt

Download Product Specification Document

This document includes all relevant product information such as:

Installation Data
Mechanical Properties
Basic Performance Data
Design Performance Data
Product Commercial Data

Download ETA Approval Document

This document was issued by the Technical and Test Institute for Construction – Prague, and contains information such as:

Technical description of the product
Specification of the intended use
Performance of the product

Applications

• Cladding restraints
• Consoles
• Barriers
• Structural steel
• Curtain walling
• Handrails
• Heavy Plant
• Balustrading
• Passenger lifts
• Facades
• Racking systems
• Platforms
• Fencing & gates manufacturing and installation

Product Information

Size Product Code FDG Product Code Anchor   Fixture     Approval Type 
Diameter Length Max. thickness tfix for:   Hole diameter
d L hnom,red hnom,std df
[mm] [mm] [mm] [mm] [mm]
M8 R-HPTIIZF-08065/15 MTB8X65G-S 8 65 15 9 ETA / Fire
  R-HPTIIZF-08080/15 MTB8X80G-S 8 80 30 15 9 ETA / Fire
  R-HPTIIZF-08100/35 MTB8X100G-S 8 100 50 35 9 ETA / Fire
  R-HPTIIZF-08115/50 MTB8X115G-S 8 115 65 50 9 ETA / Fire
M10 R-HPTIIZF-10065/5 MTB10X65G-S 10 65 5 11 ETA / C1 & C2 / Fire
  R-HPTIIZF-10080/20 MTB10X80G-S 10 80 20 11 ETA / C1 & C2 / Fire
  R-HPTIIZF-10095/15 MTB10X95Z-S 10 95 35 15 11 ETA / C1 & C2 / Fire
  R-HPTIIZF-10115/35 MTB10X115G-S 10 115 55 35 11 ETA / C1 & C2 / Fire
  R-HPTIIZF-10130/50 MTB10X130G-S 10 130 70 50 11 ETA / C1 & C2 / Fire
M12 R-HPTIIZF-12080/5 MTB12X80G-S 12 80 5 13 ETA / C1 & C2 / Fire
  R-HPTIIZF-12100/5 MTB12X100G-S 12 100 25 5 13 ETA / C1 & C2 / Fire
  R-HPTIIZF-12120/25 MTB12X120G-S 12 120 45 25 13 ETA / C1 & C2 / Fire
  R-HPTIIZF-12135/40 MTB12X135G-S 12 135 60 40 13 ETA / C1 & C2 / Fire
  R-HPTIIZF-12150/55 MTB12X150G-S 12 150 75 55 13 ETA / C1 & C2 / Fire
M16 R-HPTIIZF-16105/10 MTB16X105G-S 16 105 10 18 ETA / C1 & C2 / Fire
  R-HPTIIZF-16125/5 MTB16X125G-S 16 125 25 5 18 ETA / C1 & C2 / Fire
  R-HPTIIZF-16140/20 MTB16X140G-S 16 140 40 20 18 ETA / C1 & C2 / Fire
  R-HPTIIZF-16180/60 MTB16X180G-S 16 180 80 60 18 ETA / C1 & C2 / Fire
  R-HPTIIZF16220/100 MTB16X220G-S 16 220 120 100 18 ETA / C1 & C2 / Fire
M20 R-HPTIIZF-20125/5 MTB20X125G-S 20 125 5 22 ETA / Fire
  R-HPTIIZF-20160/20 MTB20X160G-S 20 160 40 20 22 ETA / Fire
  R-HPTIIZF-20200/60 MTB20X200G-S 20 200 80 60 22 ETA / Fire